{
    "componentChunkName": "component---src-templates-product-page-tsx",
    "path": "/product/46d37c67-961f-4a2a-93ea-94a360e6fb12",
    "result": {"data":{"spapi":{"getListingDetail":{"model":"","productId":null,"listingId":"46d37c67-961f-4a2a-93ea-94a360e6fb12","productName":"Alan Wire Aluminum THHN","firmLogoUrl":"https://spceus1pd01spfilevrsto01.blob.core.windows.net/sp-verified/76e6dd15-ec9b-4967-ae3c-405fe4d51a0a/images/profileInfo/GPoCBKWvQJu8zdFiaHM8_AlanWireLogo-01.png","firmId":"76e6dd15-ec9b-4967-ae3c-405fe4d51a0a","firmName":"Alan Wire Company","firmPartnershipTypes":[null],"categories":["Conduits","Electrical Equipment","Electrical"],"specAgentProductTypeId":16441,"productType":"UL ZLGR - Type THHN Insulated Wire","submissionStatus":"Premium MasterSpec Review","isActive":true,"isPremiumPlus":false,"buildingTypes":["Airports and Runways","Automotive Facility","Data Center","Convention Center","Courthouse","Dormitory","Exercise Center","Fire Station","Gymnasium","Hospital or Healthcare","Hotel","Laboratory","Library","Manufacturing","Mixed Use","Motel","Motion Picture Theatre","Museum","Office","Parking Garage","Penitentiary","Performing Arts Theater","Police Station","Post Office","Rail and Transit Systems","Religious Building","Retail","Roads, Highways, and Bridges","School or University","Schools (K-12)","Sports Arena","Town Hall","Transportation","Universities","Utility and Pipeline Infrastructure","Warehouse","Water and Wastewater Treatment Plants","Workshop"],"firstPublished":"2025-05-01T19:52:03.411Z","lastPublished":"0001-01-01T00:00:00.000Z","shortDescription":null,"longDescription":"<b>CONSTRUCTION</b><div><b>» Conductors: </b>Compact bare aluminum stranded conductors, Aluminum Alloy 8000 series per ASTM B800, B801, and ASTM B836.</div><div><b>» Insulation and Jacket:</b> Color-coded PVC insulation, heat and moisture resistant, flame retardant per UL-83 and UL-758 with a nylon jacket per UL-83 and UL-758 made with a friction reducing jacket to aid in the installation process.<br><div><br></div></div><div><b>APPLICATIONS</b></div><div>Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial and industrial applications as specified in the National Electrical Code and has a 600V rating. THHN/THHN-2 conductors are suitable for use in wet or dry locations not to exceed 90C or not to exceed 75C in oil or coolants. All sizes are made with a friction-reducing compound to aid in the installation process.<br></div><div><br></div><div><b>SPECIFICATIONS</b></div><div>» ASTM B800, B801, B836\n» UL 83, UL 758, UL 1581, UL 1685, UL 2556\n» Federal Specification A-A-59544\n» All sizes UL VW-1 Flame test, FT-1, UL 1685 FT4\n» RoHS compliant\n» CT rated sizes 1/0 and larger, IEEE 1202 FT4\n» UL Listing #E66636<br></div><div>» All sizes rated gasoline and oil resistant II and are sunlight resistant\n» ARRA 2009 Section 1605 “Buy American” compliant\n» CSA C22.2 No. 75 Thermoplastic Insulated Wire &amp; Cables\n» ICEA s-95 (NEMA WC70) power cable rates 2000 volts or less for for the distribution of electrical energy\n» C(UL) approval on all sizes\n» MasterSpec Division 26 Sections 260519<br></div>","sectionNumber":"260519","sectionTitle":"LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES","sectionName":"260519 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES","type":"Premium MasterSpec","lastUpdated":"2025-10-06T16:02:16.627Z","properties":[{"options":[{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"c1e00df0-9d52-4aed-b8ef-91348a83cf7e","value":"Copper"},{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"b047fd2e-2391-4e5e-9585-0e5677e33495","value":"Aluminum"},{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"a4a53f3a-ae29-48e8-8679-785e0c081952","value":"Copper-clad aluminum"}],"optionGroups":[{"groupId":"3068a6d1-636d-44a3-bc95-da7c001181f8","prefix":"","postfix":"","options":[{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"c1e00df0-9d52-4aed-b8ef-91348a83cf7e","value":"Copper"},{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":true,"optionId":"b047fd2e-2391-4e5e-9585-0e5677e33495","value":"Aluminum"},{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"a4a53f3a-ae29-48e8-8679-785e0c081952","value":"Copper-clad aluminum"}]}],"propertyId":"822d937a-ac67-481a-9f0b-90bf175eacf5","propertyName":"Standard Features|Conductor Material","isPremiumPlus":false},{"options":[{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"e8a0137c-a588-4e6a-bcbd-73d5fe65adf4","value":"As indicated on the Drawings."}],"optionGroups":[{"groupId":"7603a74d-d528-45fe-b74a-044d3bf0c23d","prefix":"","postfix":"","options":[{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"e8a0137c-a588-4e6a-bcbd-73d5fe65adf4","value":"As indicated on the Drawings."}]}],"propertyId":"7a3cdfae-addf-4588-8200-0d8488aeed97","propertyName":"Standard Features|Conductor Size","isPremiumPlus":false},{"options":[{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"f63c8866-7010-4707-9a5b-f0fb5e88e292","value":"14 AWG"},{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"22ec8b2f-41fc-427f-abdf-c5def4f805fc","value":"12 AWG"},{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"e074ee01-56bd-49b0-b8b3-72fd6f8d8c54","value":"10 AWG"}],"optionGroups":[{"groupId":"a36a206e-f6e2-4ba2-8293-a017e69d2249","prefix":"","postfix":"","options":[{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"f63c8866-7010-4707-9a5b-f0fb5e88e292","value":"14 AWG"},{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"22ec8b2f-41fc-427f-abdf-c5def4f805fc","value":"12 AWG"},{"isOther":false,"isPremium":false,"isPremiumPlus":false,"isSupported":false,"optionId":"e074ee01-56bd-49b0-b8b3-72fd6f8d8c54","value":"10 AWG"}]}],"propertyId":"5d972997-e279-417d-9698-bed6b6c6a0a4","propertyName":"Standard Features|Conductor Size|Minimum Conductor Size","isPremiumPlus":false}],"images":[{"id":"bfb3c9d6-eb00-4d03-bb41-d5bd819bee02","filename":"https://spceus1pd01spfilevrsto01.blob.core.windows.net/sp-verified/76e6dd15-ec9b-4967-ae3c-405fe4d51a0a/images/products/46d37c67-961f-4a2a-93ea-94a360e6fb12/vbtBrL6XT7GkFIku7TUm_AL+THHN+800w+x+600h.png","isPrimary":true,"order":0,"originalFilename":"AL THHN 800w x 600h.png"}],"videos":[],"webLinks":[{"order":0,"type":"Product Page with Specifications","url":"https://www.alanwire.com/products/aluminum/industry-aluminum/industrial-aluminum/aluminum-thhn/"},{"order":0,"type":"Safety Data Sheet","url":"https://www.alanwire.com/resources/material-safety-data-sheets/"},{"order":0,"type":"Website","url":"https://alanwire.com"}],"catalogs":null,"manufacturerDocs":[],"partnershipLinks":[{"level":null,"name":null,"partnerType":null,"url":"https://www.transparencycatalog.com/company/undefined"},{"level":null,"name":null,"partnerType":null,"url":"https://www.transparencycatalog.com/company/undefined"},{"level":null,"name":null,"partnerType":null,"url":"https://www.transparencycatalog.com/company/undefined"},{"level":null,"name":null,"partnerType":null,"url":"https://www.transparencycatalog.com/company/undefined"},{"level":null,"name":null,"partnerType":null,"url":"https://www.transparencycatalog.com/company/undefined"},{"level":null,"name":null,"partnerType":null,"url":"https://www.transparencycatalog.com/company/undefined"},{"level":null,"name":null,"partnerType":null,"url":"https://www.transparencycatalog.com/company/undefined"}],"canAutoGenerateProductSpecification":"True"}}},"pageContext":{"listingId":"46d37c67-961f-4a2a-93ea-94a360e6fb12"}},
    "staticQueryHashes": []}